Telecommunications Power

Needs and Product Solutions

RISING EXPECTATIONS

more-subscribers-rising

As more devices and subscribers come online, expectations for high levels of service continuity increase. Ensuring reliable power becomes a challenge. Reserve battery systems provide power and efficient normal operation. To ensure uninterupted service, an effective power maintenance program must be implemented. Midtronics industry-leading technology solutions assure accurate and efficient maintenance of your reserve battery systems.

Solution

Midtronics industry-leading technology solutions assure accurate and efficient maintenance of your reserve battery systems.

THE BOTTOM LINE

The Bottom Line

Cost effective management is becoming more and more critical for operators everywhere. Batteries are a substantial expense, and maximizing life and utilization of these ubiquitous systems can impact the bottom line.

Solution

An effective management program based on Midtronics equipment and data management software can ensure timely replacement and cost savings.

STREAMLINED ANALYSIS

Streamlined Analysis

With more extensive networks and increased demands on time, streamlined analysis is key to proper decision making with regard to maintenance and infrastructure.

Solution

A Midtronics specialized, central battery asset management system can improve visibility of performance and enhance decision making, saving time and money.

Midtronics Product Solutions

celltronlogo product

CELLTRON Portable Battery Analyzers

CELLTRON ADVANTAGE

MODULAR STATIONARY POWER BATTERY TESTER CELLTRON ADVANTAGE
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  •  

  • Test Range:
  • 100 - 19,990 mhos
  •  

  • Test Data Storage:
  • Unlimited internal memory USB to flash drive or PC
  •  

  • Test Data Transfer To PC:
  • USB, two way communication with SW for setup & download
  • Capacity Test Manager:
  • Voltage and time capture
  •  

  • Battery Reference Developer
  • AC Ripple Suppression Technology
  • Full Multimedia / Scope Function
  • Field Upgradable Software
  • Generator/Fleet Vehicle Battery Testing Capability
  • Integrated Temperature Measurement
  • Variation Based Analysis of Conductance vs. Baseline
Learn More

CELLTRON ULTRA

CRITICAL POWER BATTERY TESTER CELLTRON ULTRA
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  •  

  • Test Range:
  • 100 - 19,990 mhos
  •  

  • Test Data Storage:
  • Removable SD memory card stores 500 strings/locations of 480 tests
  • Test Data Transfer To PC:
  • InfraRed data transfer SD memory card
  •  

  • Capacity Test Manager:
  • Voltage and time capture
  •  

  • Battery Reference Developer
  • AC Ripple Suppression Technology
  • Full Multimedia / Scope Function
  • Field Upgradable Software
Learn More

CELLTRON ADVANCED

Celltron_Advanced
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  •  

  • Test Range:
  • 100 - 19,990 mhos
  • Test Data Storage:
  • 16 strings / memory locations of 480 test results
  •  

  • Test Data Transfer To PC:
  • InfraRed data transfer
  •  

  • Midtronics Service Center upgradable software
Learn More

CELLTRON ESSENTIAL

essential browse
  • Key Application:
  • Telecom OSP (Outside Plant)
  •  

  • Test Range:
  • 100 - 19,990 mhos
  • Test Data Storage:
  • 1 string / memory locations of 480 test results
  •  

  • Test Data Transfer To PC:
  • Not available, IR printing only
  •  

  • Midtronics Service Center upgradable software
Learn More
Cellguard product log

CELLGUARD Battery Monitoring System

CELLGUARD

CELLGUARD BATTERY MONITORING SYSTEM
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  •  

  • Communications Interfaces:
  • Ethernet 10 Mbps
  • RS232 or serial USB ( @ 57.6 kbps)
  • 802.15.4 compliant RF transport
  • @ 2.4 GHz Radio Band
  •  

  • Temperature:
  • Operating Temperature
  • ( 0° C to +65° C)
  • Storage Temperature
  • ( -10° C to +80° C)
  •  

  • Power Requirements:
  • Base Coordinator Unit Power:
  • Powered by 9 V DC wall plug adaptor
  • or powered from VTC (optional)
  • VTC Unit Power:
  • Powered from the battery (< 60 mA)
  • 2 V Sensor Power:
  • Powered from the battery under surveillance
  • 12 V Sensor Power:
  • Powered from the battery under surveillance
  •  

  • Conductance Measurement Range:
  • 100 to 15,000 Siemens (cell mhos)
  •  

  • Strap Resistance Measurement:
  • 2 micro Ohms minimum
  •  

  • Test Current:
  • 2V & 12V Sensors
  • Test current is approximately 5 Amps RMS
  • Voltage Measuring Characteristics:
  • Sensor Voltage range: 1.4 V to 2.5 V per cell
  • Resolution: +/- 20 mV
  •  

  • Sensor Negative Battery:
  • Post Temperature Reading
  • Temperature Range: ( 0° C to +65° C)
  • Measurement Accuracy: (+/- 2° C)
  •  

  • String Voltage Measurement:
  • Input Range: 42 to 600 Volts DC
  • AC Ripple
  • Peak AC Ripple Detection
  •  

  • String Current Measurement:
  • Float State: 300 milli-Amps to 10 Amps
  • Charge State: 10 to 200 Amps
  • Discharge State: 10 to 200 Amps
  •  

  • Physical Dimensions:
  • Base Coordinator Unit:
  • 5.08 in x 5.25 in x 2.25 in
  • 12.9 cm x 13.3 cm x 5.7 cm
  • VTC String Monitor:
  • 5.08 in x 5.25 in x 2.25 in
  • 12.9 cm x 13.3 cm x 5.7 cm
  • 2 V & 12 V Sensor:
  • 4.45 in x 3.15 in x 1.5 in
  • 11.3 cm x 8 cm x 3.8 cm
Learn More

CELLGUARD TRACE

celltrace browse
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  •  

  • Battery Conductance Range:
  • 100 s < Siemens < 4,000 s for 12-volt batteries
  •  

  • Battery Voltage Range:
  • 10.500 V < V < 15.000 V (12-volt battery)
  • Note: Cellguard Trace is capable of reading above this range
  •  

  • Battery Temperature Measurement Range:
  • -20°C (-4°F) < T < 70°C (158°F)
  • String Voltage:
  • 21 V < V < 31 V for 24-volt operation
  • 42 V < V < 62 V for 48-volt operation
  •  

  • Module Power Source:
  • CELLGUARD Trace is powered by the batteries under test
  •  

  • Module Dimensions:
  • 9.5” in x 3“ in x 1.25” in
  •  

  • Module Environment Requirements:
  • Operating Temperature: -20˚C (-4˚F) to 70˚C (158˚F)
  • Operating Humidity: 0-95% non- condensing
Learn More
CELLTRAQ PRODUCT LOGO

Data Management

CELLTRAQ

celltraq
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  •  

  • Windows Operating System
  •  

  • Tomcat Web Server:
  • 2GB RAM or above (4GB recommended)
  • CPU:
  • 2.6 GB or above
  • SQL Server Database:
  • 4GB RAM or above (8GB recommended)
  •  

  • Installation CD provides, in addition to the Server Application, Database, and SMTP Tester Interface:
  • Installation Manual
  • JDBC-SQL Server Driver
  • Java Development Kit (JDK)
  • Tomcat
Learn More

BATTERYNET

batterynet preview
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  • Industry’s proven source for effective battery data management and report automation
  • More consistent, effective and efficient battery maintenance
  • Professional level reports
  • Proven efficiency in providing early warning on battery degradation
  • Establishes battery inventory stocking levels based on unit density and change
Learn More

FACILITYWARE

facilityware
  • Key Application:
  • Telecom Central Office
  • Telecom OSP (Outside Plant)
  • Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
  • Centralized record keeping and maintenance data on everything (outside of batteries) that is key to a well-run operation.
  • User configurable database and reporting tools
  • Collects and reports on critical information regarding generators, switchgear, power boards, HVAC and CRAC units, and much more
  • Reliability in scheduling the next maintenance or responding to an audit request
Learn More
  
Select the product(s) that needs service or support:
  
  
  
  
Preferred method of contact:
  
  

Enter the code in the image:
  
Select:
  
  
  
  
Preferred method of contact:
  
  

Enter the code in the image: